The Swift PRO Elite is a robust optical measuring microscope, ideal for measuring and inspecting intricate and difficult-to-view samples.
Applications
Customers around the world use the Swift Pro Elite for a wide range of non-contact measurement applications, including:
– Plastic parts (connectors, bottles, moulding)
– Medical devices (implants, tubing, stents)
– Precision engineered parts (aerospace, automotive, defence)
– Watchmaking
– General manufacturing
Increase Operator Performance and Productivity with Dynascope® technology
Designed with an ergonomic body position, the Swift Pro Elite offers ease of use, comfort and significantly reduces user fatigue and eyestrain. The Dynascope® technology allows operators to take accurate measurements whilst wearing prescriptive glasses, safety goggles and contact lenses. Businesses choose the Swift Pro Elite because they know their operators are more efficient, more accurate and more productive.
Simple. Rugged. Precise.
The Swift PRO Elite has been designed to cope with the demands of a busy production environment and includes Vision Engineering’s proven 200mm x 100mm precision measuring stage.
Non-Linear Error Correction (NLEC) is the most accurate correction method available and uses a software algorithm to calculate and correct any errors across the measuring stage. All measuring stages are factory-set with NLEC calibration prior to installation.
With space at a premium, the Swift PRO Elite’s small footprint doesn’t take up much room, yet can make a big difference to your production quality.
This product is available to view in our virtual demo.
Click to the right if you’d like to see the product in-situ within an SMT line, where you can also view a 3D file and watch a short video introduction.
If you’d like more information first click below.
| Swift Pro Elite | |
| Measurement Uncertainty | (X, Y)§ Uncertainty formula U952D = 5+(6.5L/1000)µm Where L = length in mm, using controlled conditions with 100x magnification at the standard measuring plane. Increased accuracies may be obtained over shorter measuring lengths and by in situ system calibration (Z) Z-axis accuracy 10μm, using controlled conditions with 100x magnification |
| Optics | Patented twin pupil monoscopic Dynascope™, infinity corrected optical system, with pre-centred crossline graticule to both eyes. § Option of custom designed graticule, pre-centred to one eye |
| Magnification Options (System Total) | Quick change magnification options: – 1x objective, 10x total magnification – 2x objective, 20x total magnification – 5x objective, 50x total magnification – 10x objective, 100x total magnification |
| Measuring Stage | Precision measuring stage, with factory-set Non-Linear Error Correction (NLEC) calibration as standard. |
| Measuring Range | – (X, Y): 200mm x 100mm or 150mm x 100mm stage options – (Z) for 3 axis variant: 98mm |
| Maximum Load | 10Kg |
| Encoder resolution | X = 1µm Y = 1µm Z = 0.5µm |
| Illumination | Substage and surface illumination provides the ability to measure both profile and surface features. – Enhance substage illumination – Quadrant Surface Illumination with cool, corrected colour temperature LEDs – Illumination control via Software – Substage iris control |
| Swift Pro Elite | |
| Measurement Uncertainty | (X, Y)§ Uncertainty formula U952D = 5+(6.5L/1000)µm Where L = length in mm, using controlled conditions with 100x magnification at the standard measuring plane. Increased accuracies may be obtained over shorter measuring lengths and by in situ system calibration (Z) Z-axis accuracy 10μm, using controlled conditions with 100x magnification |
| Optics | Patented twin pupil monoscopic Dynascope™, infinity corrected optical system, with pre-centred crossline graticule to both eyes. § Option of custom designed graticule, pre-centred to one eye |
| Magnification Options (System Total) | Quick change magnification options: – 1x objective, 10x total magnification – 2x objective, 20x total magnification – 5x objective, 50x total magnification – 10x objective, 100x total magnification |
| Measuring Stage | Precision measuring stage, with factory-set Non-Linear Error Correction (NLEC) calibration as standard. |
| Measuring Range | – (X, Y): 200mm x 100mm or 150mm x 100mm stage options – (Z) for 3 axis variant: 98mm |
| Maximum Load | 10Kg |
| Encoder resolution | X = 1µm Y = 1µm Z = 0.5µm |
| Illumination | Substage and surface illumination provides the ability to measure both profile and surface features. – Enhance substage illumination – Quadrant Surface Illumination with cool, corrected colour temperature LEDs – Illumination control via Software – Substage iris control |
The Swift PRO Elite comes with a precision measuring stage offering 200 mm × 100 mm range in X and Y; For the 3-axis (Z) variant, Z-axis travel is 98 mm.
The system uses Vision Engineering’s patented twin-pupil, monoscopic Dynascope™ optics. The magnification choices are quick-change objectives:
The stage can support up to 10 kg of part or load. It features factory-set Non-Linear Error Correction (NLEC) calibration, which corrects for mechanical and stage errors across its full travel. This ensures consistent precision even for more demanding inspection tasks.
Illumination options include:
The Swift PRO Elite occupies a relatively compact footprint given its capabilities: dimensions are approximately 680 mm (width) × 515 mm (depth) × 480 mm (height). As it includes stage motion and optics, a stable bench / vibration-controlled surface helps in getting its full accuracy.